The Sungrow SG30CX Multi-MPPT String Inverter for 1000 Vdc System
Key Features:
HIGH YIELD
- 3 MPPTs with max. efficiency 98.6%
- Compatible with bifacial module
- Built-in PID recovery function
SMART O&M
- Touch free commissioning and remote
firmware upgrade - Smart IV curve scanning
- Fuse free design with smart string current
monitoring
SAVED INVESTMENT
- Compatible with Al and Cu AC cables
- DC 2 in 1 connection enabled
- Cable free communication with optional WLAN
PROVEN SAFETY
- IP66 and C5 anti-corrosion grade
- Type II SPD for both DC and AC
- Satisfied global safety and grid code
Specification | Details |
---|---|
Recommended max. PV input power | 45 kW |
Max. PV input voltage | 1100 V ** |
Min. PV input voltage / Start-up input voltage | 200 V / 250 V |
Rated PV input voltage | 585V |
MPP voltage range | 200 – 1000 V |
No. of independent MPP inputs | 3 |
No. of PV strings per MPPT | 2 |
Max. PV input current | 78 A (26 A / 26 A / 26 A) |
Max. DC short-circuit current | 120 A (40 A / 40 A / 40 A) |
Output (AC) | 29.9 kVA |
Max. AC Output power | 29.9 kVA |
Rated AC output apparent power | 48.15 A |
Max. AC output current | 3 / N / PE, 230 / 400 V |
Rated AC voltage | 312 – 528 V |
AC voltage range | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
Rated grid frequency / Grid frequency range | < 3 % (at rated power) |
Harmonic (THD) | > 0.99 / 0.8 leading – 0.8 lagging |
Power factor at rated power / Adjustable power factor | 3 / 3-PE |
Feed-in phases / connection phases | 98.6 % / 98.3 % |
Efficiency | Yes |
Max. efficiency / European efficiency | Yes |
Protection | Yes |
DC reverse polarity protection | Yes |
AC short circuit protection | Yes |
Leakage current protection | Yes |
Grid monitoring | No |
Ground fault monitoring | Yes |
DC switch | Yes |
AC switch | Yes |
PV string monitoring | DC Type II / AC Type II |
Q at night function | 702 * 595 * 310 mm |
PID recovery function | 50 kg |
DC Terminal Protective Cover | Transformerless |
Communication dongle (EyeM4) | IP66 |
Surge Protection | ≤2 W |
General Data | -30 to 60 ℃ (> 45 ℃ derating) |
Dimensions (W*H*D) | 0 – 100 % |
Weight | Smart forced air cooling |
Topology | 4000 m (> 3000 m derating) |
Degree of protection | LED, Bluetooth+APP |
Night power consumption | RS485 / WLAN / Optional: Ethernet |
Operating ambient temperature range | MC4 (Max. 6 mm²) |
Allowable relative humidity range | OT or DT terminal (Max.70 mm²) |
Cooling method | IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, IEC 61000-6-3, AS/NZS 4777.2:2020 |
Max. operating altitude | Q at night function, LVRT, HVRT, active & reactive power control and power ramp rate control |
Specs
Recommended max. PV input power
- 45 kW
Max. AC Output power
- 29.9 kVA
Max. Efficiency
- 98.6%
Operating Temperature
- -30°C to 60°C
Dimensions
- 702 * 595 * 310 mm
Inverter Weight
- 50 kg